{"id":2062,"date":"2026-07-30T12:18:42","date_gmt":"2026-07-30T12:18:42","guid":{"rendered":"https:\/\/zeeyielec.com\/?p=2062"},"modified":"2026-07-30T12:24:41","modified_gmt":"2026-07-30T12:24:41","slug":"mv-bushing-terminal-connection-errors-rework","status":"publish","type":"post","link":"https:\/\/zeeyielec.com\/de\/mv-bushing-terminal-connection-errors-rework\/","title":{"rendered":"Fehler beim Anschluss von MV-Durchf\u00fchrungen und Vermeidung von Nacharbeiten (korrigiert \u2013 zur Einhaltung der Wortbegrenzung gek\u00fcrzt)"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">What Counts as a Terminal Connection Error on an MV Bushing<\/h2>\n\n\n\n<p>MV bushing terminal connection errors are faults that originate at the bolted or clamped interface between a bushing&#8217;s terminal stud and the external conductor lug \u2014 not within the bushing&#8217;s internal insulation system. This distinction matters in the field: both fault types can show similar symptoms during a walkdown (heat discoloration, oil weeping, arcing marks), but they call for different corrective actions. A degraded internal dielectric path requires bushing replacement; a connection error is usually correctable through inspection, cleaning, and reseating without touching the bushing body.<\/p>\n\n\n\n<p>The terminal interface typically consists of a threaded copper or bronze stud, a flat or dished contact washer, and a mating lug, torqued to a manufacturer-specified value \u2014 commonly 40 N\u00b7m\u201390 N\u00b7m depending on stud diameter and current rating. Thread damage, an improperly seated washer, a misaligned lug face, or trapped contamination all qualify as connection errors.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Distinguishing Terminal Errors from Bushing Body Defects<\/h3>\n\n\n\n<p>A connection error produces a resistance or thermal anomaly confined to the stud-lug interface, resolving once the joint is cleaned and correctly retorqued. A body defect \u2014 internal tracking or a degraded seal \u2014 persists regardless of terminal work and often shows a rising trend on periodic power-factor or partial-discharge testing.<\/p>\n\n\n\n<p>In one recurring field pattern, a bushing flagged during a thermal survey for a terminal-area hot spot was found, on disassembly, to have a lug seated at a slight angle against the contact washer \u2014 reducing effective contact area well below the joint&#8217;s rated cross-section. Reseating the lug square and retorquing to spec resolved the anomaly without bushing replacement.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"559\" src=\"https:\/\/zeeyielec.com\/wp-content\/uploads\/2026\/07\/zeeyielec-mv-bushing-terminal-connection-errors-figure-01.webp-1024x559.webp\" alt=\"Cross-section diagram of MV bushing terminal stud, contact washer, and mating lug interface\" class=\"wp-image-2064\" srcset=\"https:\/\/zeeyielec.com\/wp-content\/uploads\/2026\/07\/zeeyielec-mv-bushing-terminal-connection-errors-figure-01.webp-1024x559.webp 1024w, https:\/\/zeeyielec.com\/wp-content\/uploads\/2026\/07\/zeeyielec-mv-bushing-terminal-connection-errors-figure-01.webp-300x164.webp 300w, https:\/\/zeeyielec.com\/wp-content\/uploads\/2026\/07\/zeeyielec-mv-bushing-terminal-connection-errors-figure-01.webp-768x419.webp 768w, https:\/\/zeeyielec.com\/wp-content\/uploads\/2026\/07\/zeeyielec-mv-bushing-terminal-connection-errors-figure-01.webp-18x10.webp 18w, https:\/\/zeeyielec.com\/wp-content\/uploads\/2026\/07\/zeeyielec-mv-bushing-terminal-connection-errors-figure-01.webp.webp 1408w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">Cross-sectional view of a medium-voltage bushing terminal assembly showing the stud, contact washer, and mating lug forming the current-carrying joint.<\/figcaption><\/figure>\n\n\n\n<p><strong>[Expert Insight]<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>A hot spot confined to one edge of the joint usually points to misalignment, not a bad connection overall<\/li>\n\n\n\n<li>Don&#8217;t assume oil weeping near a terminal means the bushing has failed \u2014 check the joint first<\/li>\n\n\n\n<li>Power-factor and partial-discharge trends distinguish a body defect from a terminal issue faster than visual inspection alone<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Why These Errors Develop During and After Installation<\/h2>\n\n\n\n<p>A bolted joint doesn&#8217;t conduct current across its full apparent contact area \u2014 it conducts through microscopic asperity points where the surfaces actually touch. Clamping force increases real contact area by flattening these asperities, which is why torque accuracy, not surface size, determines joint resistance.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">The Mechanics of Contact Degradation<\/h3>\n\n\n\n<p>An under-torqued joint \u2014 typically below roughly 80% of specified value \u2014 keeps real contact area small and resistance elevated, running hotter under load than a correctly torqued joint. Over-torquing deforms the contact washer or cracks a porcelain terminal boss, which paradoxically reduces contact pressure once the material relaxes.<\/p>\n\n\n\n<p>Joint resistance R is inversely related to real contact area A<sub>c<\/sub>, which scales with clamping force F<sub>c<\/sub> raised to a fraction less than 1 (typically F<sub>c<\/sub><sup>0.5<\/sup>\u2013F<sub>c<\/sup>), so resistance drops sharply as force rises from zero but flattens at higher torque \u2014 meaning added torque beyond spec yields diminishing electrical benefit while raising mechanical risk.<\/p>\n\n\n\n<p>Thermal cycling compounds this: copper, aluminum, and steel hardware expand and contract at different rates, gradually loosening a joint torqued correctly at installation \u2014 a mechanism generally described in bolted-joint engineering literature as thermal cycling-induced preload loss or self-loosening.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Common MV Bushing Terminal Connection Errors in the Field<\/h2>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"559\" src=\"https:\/\/zeeyielec.com\/wp-content\/uploads\/2026\/07\/zeeyielec-mv-bushing-terminal-connection-errors-figure-02.webp-1024x559.webp\" alt=\"Comparison of correctly seated versus misaligned cross-threaded bushing terminal connection\" class=\"wp-image-2065\" srcset=\"https:\/\/zeeyielec.com\/wp-content\/uploads\/2026\/07\/zeeyielec-mv-bushing-terminal-connection-errors-figure-02.webp-1024x559.webp 1024w, https:\/\/zeeyielec.com\/wp-content\/uploads\/2026\/07\/zeeyielec-mv-bushing-terminal-connection-errors-figure-02.webp-300x164.webp 300w, https:\/\/zeeyielec.com\/wp-content\/uploads\/2026\/07\/zeeyielec-mv-bushing-terminal-connection-errors-figure-02.webp-768x419.webp 768w, https:\/\/zeeyielec.com\/wp-content\/uploads\/2026\/07\/zeeyielec-mv-bushing-terminal-connection-errors-figure-02.webp-18x10.webp 18w, https:\/\/zeeyielec.com\/wp-content\/uploads\/2026\/07\/zeeyielec-mv-bushing-terminal-connection-errors-figure-02.webp.webp 1408w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">Side-by-side comparison of a correctly seated MV bushing terminal connection and a misaligned, cross-threaded connection prone to rework.<\/figcaption><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Cross-Threading and Thread Damage<\/h3>\n\n\n\n<p>Most common in confined switchgear or pad-mount enclosures with limited hand clearance, and more likely on reconnection than first-time installation. Once threads are damaged, torque readings become unreliable \u2014 the wrench may show the target 40 N\u00b7m\u201390 N\u00b7m while actual clamping force at the contact face is lower, since torque is partly consumed overcoming thread friction.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Contact Face Misalignment<\/h3>\n\n\n\n<p>A lug seated even a few degrees off perpendicular concentrates current through a smaller region of the interface. A hot spot localized to one edge of an otherwise correctly torqued joint is a strong indicator of this.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Under-Torque and Over-Torque on Reconnection<\/h3>\n\n\n\n<p>Crews reconnecting by feel rather than with a calibrated tool risk under-torquing (mechanically loose, prone to ratcheting) or over-torquing a reused fastener whose threads are already weakened.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Contamination Introduced During Rework<\/h3>\n\n\n\n<p>Dust, moisture, or solvent residue left on contact surfaces creates a thin resistive film. Unlike the other error types, this often passes initial inspection and surfaces later as a slowly rising resistance trend \u2014 why periodic rechecking after any rework matters.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Diagnosing a Suspected Terminal Connection Error Before Re-Energization<\/h2>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"559\" src=\"https:\/\/zeeyielec.com\/wp-content\/uploads\/2026\/07\/zeeyielec-mv-bushing-terminal-connection-errors-figure-03.webp-1024x559.webp\" alt=\"Diagnostic flow diagram for MV bushing terminal connection error detection sequence\" class=\"wp-image-2066\" srcset=\"https:\/\/zeeyielec.com\/wp-content\/uploads\/2026\/07\/zeeyielec-mv-bushing-terminal-connection-errors-figure-03.webp-1024x559.webp 1024w, https:\/\/zeeyielec.com\/wp-content\/uploads\/2026\/07\/zeeyielec-mv-bushing-terminal-connection-errors-figure-03.webp-300x164.webp 300w, https:\/\/zeeyielec.com\/wp-content\/uploads\/2026\/07\/zeeyielec-mv-bushing-terminal-connection-errors-figure-03.webp-768x419.webp 768w, https:\/\/zeeyielec.com\/wp-content\/uploads\/2026\/07\/zeeyielec-mv-bushing-terminal-connection-errors-figure-03.webp-18x10.webp 18w, https:\/\/zeeyielec.com\/wp-content\/uploads\/2026\/07\/zeeyielec-mv-bushing-terminal-connection-errors-figure-03.webp.webp 1408w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">Three-stage diagnostic flow for MV bushing terminal connections, progressing from visual inspection through torque verification to thermal resistance testing.<\/figcaption><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Visual and Dimensional Checks<\/h3>\n\n\n\n<p>A close inspection of stud threads, washer, and lug face under adequate lighting \u2014 with a magnifier or borescope in confined compartments \u2014 catches thread galling, an out-of-square lug seat, or discoloration from prior overheating. Feeler gauges confirm the lug sits flush within roughly 0.1 mm\u20130.3 mm of flatness tolerance.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Torque Verification<\/h3>\n\n\n\n<p>A calibrated torque wrench confirms the joint holds its specified 40 N\u00b7m\u201390 N\u00b7m value. A joint requiring noticeably less torque to reach target, or that doesn&#8217;t hold under a brief re-check, indicates thread damage or contact-face deformation the visual check may have missed.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Thermal and Contact Resistance Checks<\/h3>\n\n\n\n<p>A micro-ohmmeter measures contact resistance directly, while an infrared camera or thermal indicator identifies hot spots under load <a href=\"https:\/\/standards.ieee.org\/ieee\/C57.19.100\/3946\/\" target=\"_blank\" rel=\"noopener\">IEEE C57.19.100<\/a> provides general principles for evaluating bushing performance in service, though its scope is oriented toward higher-BIL power apparatus bushings rather than MV distribution-class terminals specifically, and it does not define terminal-specific micro-ohm resistance thresholds. Since these thresholds vary by manufacturer and stud size, teams typically compare a suspect joint against sister connections on the same transformer.<\/p>\n\n\n\n<p>A joint failing any of these three checks should be disassembled and rebuilt rather than re-torqued in place \u2014 retorquing over an already-compromised surface tends to mask the problem rather than resolve it.<\/p>\n\n\n\n<p><strong>[Expert Insight]<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Check visual and torque before thermal instrumentation \u2014 it saves time on joints that are simply loose, not damaged<\/li>\n\n\n\n<li>A joint that won&#8217;t hold torque on a quick re-check almost always has thread or washer damage<\/li>\n\n\n\n<li>Compare a suspect joint against sister connections on the same unit rather than chasing a universal resistance number<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">The Hidden Cost of Repeated Rework Cycles<\/h2>\n\n\n\n<p>Each disassembly and reconnection carries slightly more risk than the last \u2014 easy to overlook when a single rework resolves the immediate symptom but accumulates cost over the transformer&#8217;s service life.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Cumulative Wear and Diagnostic Uncertainty<\/h3>\n\n\n\n<p>Thread engagement degrades incrementally on each disassembly, particularly on softer bronze or copper-alloy studs \u2014 a stud tolerating 60 N\u00b7m cleanly on first installation may show measurable wear by the third or fourth reconnection. Contact washers can also lose flatness after repeated compression, even while looking structurally intact. A joint with undocumented rework history is harder to diagnose confidently later: if a thermal survey flags it again, the team can&#8217;t easily tell whether the anomaly is new or residual, pushing toward full disassembly rather than a faster torque-only recheck. Transformers with two or more documented reworks are often flagged for closer interval monitoring than sister units with a clean installation history.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Outage and Schedule Impact<\/h3>\n\n\n\n<p>A pad-mounted distribution transformer taken offline for a suspected terminal fault typically needs a 4-hour\u20138-hour outage window to de-energize, disassemble, inspect, and re-energize, and a repeat rework within the same cycle compounds that downtime against a utility&#8217;s outage budget. Evaluating <a href=\"https:\/\/zeeyielec.com\/transformer-accessories\/medium-voltage-bushings\/\">medium voltage bushing<\/a> hardware quality upfront \u2014 rather than treating terminal hardware as a commodity line item \u2014 reduces how often this cycle repeats.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Rework Prevention Practices for MV Bushing Terminal Connections<\/h2>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"559\" src=\"https:\/\/zeeyielec.com\/wp-content\/uploads\/2026\/07\/zeeyielec-mv-bushing-terminal-connection-errors-figure-04.webp-1024x559.webp\" alt=\"Preventive checklist infographic for MV bushing terminal rework prevention practices\" class=\"wp-image-2067\" srcset=\"https:\/\/zeeyielec.com\/wp-content\/uploads\/2026\/07\/zeeyielec-mv-bushing-terminal-connection-errors-figure-04.webp-1024x559.webp 1024w, https:\/\/zeeyielec.com\/wp-content\/uploads\/2026\/07\/zeeyielec-mv-bushing-terminal-connection-errors-figure-04.webp-300x164.webp 300w, https:\/\/zeeyielec.com\/wp-content\/uploads\/2026\/07\/zeeyielec-mv-bushing-terminal-connection-errors-figure-04.webp-768x419.webp 768w, https:\/\/zeeyielec.com\/wp-content\/uploads\/2026\/07\/zeeyielec-mv-bushing-terminal-connection-errors-figure-04.webp-18x10.webp 18w, https:\/\/zeeyielec.com\/wp-content\/uploads\/2026\/07\/zeeyielec-mv-bushing-terminal-connection-errors-figure-04.webp.webp 1408w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">A preventive checklist infographic covering hardware verification, torque staging, contact inspection, and replacement decisions for MV bushing terminals.<\/figcaption><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Verification Before First Connection<\/h3>\n\n\n\n<p>Confirm stud size, thread condition, and specified torque before the first connection. Check that the lug or busbar connector matches the terminal&#8217;s rated current \u2014 typically 200 A\u20133150 A across ZeeyiElec&#8217;s <a href=\"https:\/\/zeeyielec.com\/transformer-accessories\/medium-voltage-bushings\/\">medium voltage bushing<\/a> families \u2014 since an undersized lug forced onto an oversized stud is a common misalignment source. Reviewing requirements against a project&#8217;s <a href=\"https:\/\/zeeyielec.com\/transformer-accessories-rfq-checklist\/\">transformer accessories RFQ checklist<\/a> at the spec stage catches mismatches before hardware reaches the field.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Handling Repeated Disconnection and Reconnection<\/h4>\n\n\n\n<p>Treat every planned reconnection as a fresh installation: clean both contact surfaces, inspect thread condition, and retorque to the full specified value rather than a partial turn. Documenting each rework event \u2014 date, torque achieved, hardware condition \u2014 gives future inspections a baseline that shortens diagnostic time.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">When to Replace vs. Reuse Hardware<\/h3>\n\n\n\n<p>Hardware with thread galling, a deformed washer, or contact-face pitting should generally be replaced, not reused. Studs and washers through two or more reconnection cycles warrant closer scrutiny even if undamaged. The <a href=\"https:\/\/zeeyielec.com\/transformer-accessories-selection-guide\/\">transformer accessories selection guide<\/a> and <a href=\"https:\/\/zeeyielec.com\/iec-specification-cheat-sheet-accessory-procurement\/\">IEC specification cheat sheet<\/a> outline parameters worth confirming with a supplier before ordering replacement hardware.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Getting Terminal Connection Specs Right from the Start<\/h2>\n\n\n\n<p>Consistent hardware quality \u2014 stud tolerances, washer material, torque spec \u2014 is one of the more overlooked variables in reducing MV bushing rework. The same joint-quality principles apply across ZeeyiElec&#8217;s <a href=\"https:\/\/zeeyielec.com\/transformer-accessories\/\">transformer accessories<\/a> and <a href=\"https:\/\/zeeyielec.com\/cable-accessories\/\">cable accessories<\/a> lines, since both rely on correctly torqued, contamination-free contact interfaces for long-term reliability.<\/p>\n\n\n\n<p>For teams specifying or sourcing terminal hardware for a new project or a maintenance-driven replacement order, confirming dimensions, current rating, and torque specification at the RFQ stage \u2014 rather than after installation issues surface \u2014 is the most direct way to prevent the errors covered here. Share your bushing voltage class, terminal current rating (typically 200 A\u20133150 A), and any known rework history, and the technical team can confirm whether standard hardware meets the application or a customized terminal configuration is warranted.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Frequently Asked Questions<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">How many times can an MV bushing terminal be safely reconnected?<\/h3>\n\n\n\n<p>Most hardware tolerates a small number of reconnection cycles before thread and contact-face wear become a concern, depending on hardware material and torque history. Field teams generally treat repeated reconnection as a flag for inspection rather than routine practice.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">What are the signs of a cross-threaded MV bushing terminal?<\/h3>\n\n\n\n<p>Signs include unusual resistance during hand-starting the fastener, visible metal shavings near the thread, and a lug seating at an angle instead of flush. Any of these should stop the process and prompt a hardware check before torquing further.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Can a misaligned terminal connection cause a hot spot without tripping protection?<\/h3>\n\n\n\n<p>Yes \u2014 reduced contact area from misalignment can raise local resistance and generate heat well below fault-current thresholds, so protective devices typically won&#8217;t detect it. Thermal or infrared scanning during commissioning is the more reliable way to catch this early.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Is it safe to reuse terminal hardware after a failed connection?<\/h3>\n\n\n\n<p>It depends on the extent of thread or surface damage; lightly marked hardware may be reusable after inspection, while cross-threaded or deformed hardware should generally be replaced. The decision should weigh downtime cost against the risk of repeat failure.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">How long does a terminal connection rework typically take in the field?<\/h3>\n\n\n\n<p>A straightforward rework \u2014 inspection, cleaning, re-torquing \u2014 can often be completed within an hour or two, extending significantly if hardware replacement is required. Access constraints and outage-window limits usually drive total time more than the mechanical work itself.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Does contamination during rework affect reliability even if the connection passes initial testing?<\/h3>\n\n\n\n<p>Yes \u2014 surface contamination can pass an initial resistance or visual check and still degrade the joint over months of thermal cycling. This is why field teams treat cleanliness during rework as equally important as torque accuracy.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">What tools are needed to diagnose a suspected terminal connection error?<\/h3>\n\n\n\n<p>A calibrated torque wrench, a contact-resistance measurement tool such as a micro-ohmmeter, and an infrared camera or thermal indicators cover most field diagnostic needs, supplemented by a borescope or magnifier for visual confirmation.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>What Counts as a Terminal Connection Error on an MV Bushing MV bushing terminal connection errors are faults that originate at the bolted or clamped interface between a bushing&#8217;s terminal stud and the external conductor lug \u2014 not within the bushing&#8217;s internal insulation system. This distinction matters in the field: both fault types can show [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":2063,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6,3],"tags":[],"class_list":["post-2062","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-transformer-accessories-knowledge","category-useful"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/zeeyielec.com\/de\/wp-json\/wp\/v2\/posts\/2062","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zeeyielec.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zeeyielec.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zeeyielec.com\/de\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/zeeyielec.com\/de\/wp-json\/wp\/v2\/comments?post=2062"}],"version-history":[{"count":1,"href":"https:\/\/zeeyielec.com\/de\/wp-json\/wp\/v2\/posts\/2062\/revisions"}],"predecessor-version":[{"id":2068,"href":"https:\/\/zeeyielec.com\/de\/wp-json\/wp\/v2\/posts\/2062\/revisions\/2068"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zeeyielec.com\/de\/wp-json\/wp\/v2\/media\/2063"}],"wp:attachment":[{"href":"https:\/\/zeeyielec.com\/de\/wp-json\/wp\/v2\/media?parent=2062"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zeeyielec.com\/de\/wp-json\/wp\/v2\/categories?post=2062"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zeeyielec.com\/de\/wp-json\/wp\/v2\/tags?post=2062"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}